KEVO Power
DC Series

Modular DC fast charging, engineered for operational flexibility. Our scalable architecture minimizes maintenance downtime, maximizes site uptime, and empowers CPOs to future-proof their network with unmatched efficiency.

Contact Us
DC Series VIII DC Series VIII DC Series VIII DC Series VIII DC Series VIII
DC Charger
Modular Design 60KW to 240KW EV Charger
60kW - 240kW
Model: DC Series VIII
5-Minute Maintenance
32 Inch Advertising Screen
OCPP 1.6J / 2.0.1
IP55 Waterproof
4G / Ethernet / WIFI
POS Payment Support
High-Definition Advertising Display
Integrated 32-inch screen for dynamic media playback and revenue generation.
Smart Connectivity & OCPP
Supports 4G/Ethernet/WiFi with standard OCPP 1.6J / 2.0.1 for global integration.
Robust IP55 Protection
Professional dust-proof design, operating flawlessly in -30℃ ~ +70℃ environments.
Modular Maintenance
Independent power module design minimizes downtime and enables 5-minute fast service.
KEVO Modular Charger

Modular Design

Built for CPOs

Avoid "zombie chargers" and keep your station always online.

Traditional Charger

  • Module Failure: Affects entire system
  • Stop Charging: Station offline
  • 🕒 Long Repair Time: Hours or days
Result: Zombie Charger

KEVO Modular Charger

  • Module Failure: Isolated to single module
  • Keep Charging: Other modules work
  • Quick Maintenance: Done in ≤ 5 minutes
Result: Always Online

Modular Design, Avoid Full-System Downtime

A Single Module Fault Won't Interrupt Station Operation

1Detect Faulty Module
2Remove Faulty Module
3Choose Handling Option
Option 1: Replace Immediately
1Insert New
Module
2Push In and
Lock
3Restore Full-
Capacity
Option 2: Remove Faulty First
1Remove Faulty
Module
2Keep Slot
Empty
3Remaining Modules
Work

DC Charger Status Display

Operating Status Overview

Waiting
Idle blue flash

Standby mode with system ready.

System Ready
Charging
Charge green flash

Charging in progress, power delivered.

Charging Active
Fault
Fault red flash

Fault detected, check system.

System Fault

Product Parameters

Model KP-D60D-VIII KP-D80D-VIII KP-D120D-VIII KP-D160D-VIII KP-D180D-VIII KP-D240D-VIII
Rated Input VoltageAC380V Three-phase five-wire
Input Voltage Range380VAC ±20%
Maximum Input Current116A152A228A304A384A456A
Operating Frequency50/60Hz
Output Voltage Range50-1000VDC
Max Output Current/Connector200A250A250A300/250A300/250A300A
Rated Output Power60kW80kW120kW160kW180kW240kW
Power Allocation/SwitchingEqual power sharing
THDi≤5% (Input 380V, Output 1000V, 50%-100% Load)
Input Inrush Current≤110% of rated input current
Power Factor (PF)≥0.99 (50%-100% load); ≥0.95 (20%-50% load)
Voltage Regulation Accuracy±0.5% (-30℃ to +55℃)
Current Regulation Accuracy±1% (-30℃ to +55℃, 20%-100% load)
Output Voltage Ripple≤±1% (input voltage 85%, 100%, 115%)
Overall Efficiency≥96% (100% full-load output)
Standby Power Consumption≤15W
Cooling MethodForced air
Communication ProtocolOCPP 1.6J / 2.0.1
Charging Gun5m charging gun (customizable)
Communication Interface4G / Ethernet / WIFI
IP GradeIP55
Working Temperature-30℃ ~ 70℃
Cable Specification Ref. Cu: 3×35+2×25mm²
Al: 3×70+2×50mm²
Cu: 3×50+2×35mm²
Al: 3×95+2×70mm²
Cu: 3×95+2×70mm²
Al: 3×120+2×95mm²
Cu: 3×120+2×95mm²
Al: 3×150+2×120mm²
Cu: 3×150+2×120mm²
Al: 3×185+2×150mm²
Cu: 3×240+2×150mm²
Al: 3×300+2×240mm²

Send Us a Message